TPO vs EPDM vs PVC for Denver Commercial Flat Roofs
Last reviewed: November 22, 2026
By Red Hawk Roofing
TPO and PVC are reinforced plastic sheets whose seams are welded together with hot air. EPDM is a synthetic rubber sheet whose seams are typically made with tapes and adhesives. On the data sheets read for this page, white TPO and white PVC reflect about 80 to 87 percent of the sun's energy when new; black EPDM absorbs solar heat, and PVC is the membrane its makers describe in terms of resistance to chemicals, oils and fuels. None of the three is the right answer for every Denver building: the choice turns on what sits on and under the roof, the hail rating of the whole assembly, and, for buildings of 25,000 square feet or more, Denver's cool roof rule.
This page compares the three single-ply membranes using their ASTM specifications and the manufacturers' own technical documents, then covers modified bitumen and built-up roofing briefly. Where a statement is a manufacturer describing its own product, it is attributed to that manufacturer.
What are TPO, EPDM and PVC?
They are three single-ply roof membranes, each with its own ASTM material specification.
- TPOis thermoplastic polyolefin. ASTM D6878 covers “flexible sheet made from thermoplastic polyolefin (TPO) as the principal polymer, intended for use in single-ply roofing membranes exposed to the weather. The sheet shall contain reinforcing fabrics or scrims” (ASTM D6878).
- EPDMis ethylene-propylene-diene terpolymer, a synthetic rubber. Under ASTM D4637 the sheet “may be non-reinforced, fabric- or scrim-reinforced, or fabric-backed vulcanized rubber sheet” (ASTM D4637).
- PVCis poly(vinyl chloride). ASTM D4434 covers flexible sheet made from PVC resin, and the sheet “shall contain reinforcing fibers or reinforcing fabrics” (ASTM D4434).
All three specifications describe themselves the same way: their tests and limits are “values intended to ensure minimum quality for the intended purpose,” in the words of the TPO and PVC scopes, and roof design questions such as fire resistance and wind uplift are outside them. On its data sheets, GAF says its EverGuard TPO “Meets or exceeds the requirements of ASTM D6878” (GAF TPO data sheet) and its EverGuard PVC “Meets or exceeds the requirements of ASTM D4434, Type III” (GAF PVC data sheet). Meeting the ASTM specification is a floor for the sheet. It says nothing about how the roof was designed or installed.
| TPO | EPDM | PVC | |
|---|---|---|---|
| Material | Thermoplastic polyolefin, reinforced with fabric or scrim | Vulcanized synthetic rubber; non-reinforced, reinforced or fabric-backed | Poly(vinyl chloride), reinforced with fibers or fabric |
| ASTM specification | D6878 | D4637 | D4434 |
| Seams | Heat-welded | Typically tapes and adhesives | Heat-welded |
| Color and reflectance | White, tan, gray and other colors. One maker's white: 0.79 new, 0.70 after three years | Black; white EPDM is also sold | White, tan, gray. One maker's white: 0.87 new, 0.70 after three years |
| What its makers emphasize | Reflective surface; resistance to UV and ozone; one maker claims resistance to acids, bases and restaurant exhaust | Flexibility across temperatures; resistance to UV, ozone and weathering | Resistance to chemicals, oils and fuels; fire resistance |
Sources for the table are in the sections below. Reflectance figures are from Carlisle's data sheets for its own white TPO and white PVC and do not describe other makers' products.
How are the seams made?
TPO and PVC seams are welded; EPDM seams are bonded. Elevate, which makes both TPO and EPDM, puts the difference in one passage: “EPDM is a flexible thermoset synthetic rubber membrane that typically uses tapes and adhesives to form seams. TPO is a reinforced thermoplastic membrane with heat-welded seams” (Elevate, EPDM).
The manufacturers' data sheets describe each method. Carlisle on PVC: “Sheet seams are heat-welded together using hot-air welding equipment to create a monolithic, water-tight roof system” ( Carlisle PVC data sheet). Sika lists “Hot-air welded seams for long-term performance” among the characteristics of its Sarnafil PVC (Sika data sheet). GAF's EverGuard TPO data sheet lists among the membrane's features that it “Allows for heat-welded seams that provide greater seam strength compared to taped and other seams” ( GAF TPO data sheet), and its PVC data sheet says: “Heat-welded seams provide greater seam strength compared to taped seams” (GAF PVC data sheet). Those comparisons are GAF's own. For EPDM, Versico describes a seam tape that is laminated to the sheet edge at the factory, so that “most of the labor to create seams between membrane panels is completed in a quality-controlled, state-of-the-art environment” ( Versico EPDM bulletin).
Seams between sheets are completed on the roof, and the TPO and EPDM specifications both name “field seaming strength” among the things they leave to the roof system design.
Which membrane reflects the most heat?
On the data sheets we read, white PVC and white TPO. Two EPDM makers present black EPDM's heat absorption as an advantage in cold climates. Reflectivity is described by two numbers. The Cool Roof Rating Council: “The two basic characteristics that determine the "coolness" of a roof are solar reflectance and thermal emittance. Both properties are measured on a scale from 0 to 1, where 1 is 100% reflective or emissive.” The council rates products “both for the product's initial values and after three years of outdoor exposure” ( Cool Roof Rating Council).
The three-year figure is the lower one on the data sheets we read. Carlisle's data sheets give its white TPO a solar reflectance of 0.79 new and 0.70 after three years, and its white PVC 0.87 new and 0.70 after three years, both uncleaned (Carlisle TPO data sheet, Carlisle PVC data sheet). Carlisle's tan and gray sheets rate lower than its white ones. GAF's data sheets give its white EverGuard TPO 0.81 new and 0.75 aged, the aged figure being an interim laboratory-aged rating that stands in for the three-year value, and its white EverGuard PVC 0.87 new and 0.70 aged (GAF TPO data sheet, GAF PVC data sheet). Other manufacturers publish their own figures, and the council's directory lists rated products by brand.
Reflective is not automatically better in a cold-winter city. Elevate writes that black EPDM “can also absorb solar heat, which may be beneficial in heating-dominated climates” (Elevate, EPDM), and Versico makes the same case for its own product, calling dark-colored EPDM “the smart choice in colder climates” (Versico EPDM bulletin). Those are EPDM makers' statements. Elevate's TPO page says a reflective roof “may also help reduce building cooling needs,” depending on “climate, roof assembly, and building conditions” ( Elevate, TPO). Which effect wins on a given building is an energy-modeling question for its designer, not something a membrane brochure settles.
One labeling note: a roofing product can no longer be ENERGY STAR certified. The EPA's page states: “The ENERGY STAR specification for Roof Products was sunset on June 1, 2022” ( ENERGY STAR).
Does Denver require a cool roof on a commercial building?
On larger buildings, yes. Denver's Green Buildings Ordinance applies to new buildings of 25,000 square feet or larger, to building additions of that size, and to “Roof permits for existing buildings 25,000 square feet or larger” ( Denver, Green Buildings Ordinance). The city's energy code guidance for existing buildings spells out what that means for roof work: “If a roof permit is required for 5% or more of the roof area and the building is 25,000 sq. ft. or larger, compliance with the Green Buildings Ordinance is required.” A roof replacement then means “installing a cool roof plus a compliance option”; a roof recover means “cool roof only” ( Denver, energy code for existing commercial buildings).
Three more points from the city's two pages bear on membrane choice:
- The ordinance does not apply to every building. Its page lists the exceptions, among them parking structures and single-family homes, and says certain residential buildings need only meet the cool roof requirement.
- A roof replacement can also trigger the energy code. The roof “must be brought up to code if the existing roof assembly is part of the thermal envelope and contains insulation entirely above roof deck”. The page lists a roof recover and a roof repair as exempt from energy code compliance.
- Changing to a cool roof can change how the roof handles moisture. The city notes that “where a roof recover or replacement introduces a cool roof, the Denver Green Buildings Ordinance may require air barrier and other roof components to minimize condensation.”
For a building under 25,000 square feet, the ordinance's cool roof rule is not triggered by these thresholds. We did not open the rules that define what counts as a cool roof under the ordinance, so this page gives no reflectance value for it; confirm the current values and exceptions with the city before choosing a membrane color. Other cities have their own rules, and this page covers Denver's only.
How do the membranes handle hail?
FM Approvals rates hail resistance for the roof assembly, not for the membrane alone, under its standard FM 4470, which has three hail levels: moderate, severe and very severe. The moderate and severe tests drop a steel ball to deliver about 8 and 14 foot-pounds. The very severe test fires 2-inch ice balls at 53 to 58 foot-pounds at a roof surface chilled to 40 to 45°F, on samples that include one aged by ultraviolet light or heat, and to pass, neither the membrane nor the board beneath it may crack (FM 4470). The Insurance Institute for Business & Home Safety “recommends a hail damage resistance of Severe Hail (SH) for hail-prone areas” (IBHS).
At least part of Colorado is in the area FM treats most strictly, according to Carlisle. It writes that FM's very severe hail region takes in all or parts of a list of states that includes Colorado, and that FM based the region on “a concentration of reports of hail greater than 2 inches in diameter” ( Carlisle). FM's own map is in its Data Sheet 1-34, which we did not open; an FM-insured building's requirement comes from FM, not from this page.
Makers of all three membranes publish hail claims for their own products. Carlisle's reinforced TPO data sheet lists a “UL 2218 Class 4 hail rating” ( Carlisle TPO data sheet). Versico says one of its EPDM membranes “offers excellent weatherability and hail resistance” (Versico EPDM bulletin). Sika describes itself as “the first PVC manufacturer with Very Severe Hail (VSH) approvals over gypsum cover board” (Sika). That last phrase points at what the ratings have in common: the cover board under the membrane is part of the rated assembly. Ask for the hail rating of the assembly being proposed, with the board and attachment method named. Our guide to what size hail damages a roof covers the test standards and the other roofing materials.
On guarantees, GAF is the one maker whose guarantee documents we read. Its standard EverGuard Diamond Pledge NDL Roof Guarantee does not cover leaks caused by “Unusual weather conditions or natural disasters including, but not limited to, winds in excess of 55 miles per hour, hail, floods, hurricanes, lightning, tornados, and earthquakes, unless specifically covered by an addendum to this guarantee” (GAF Diamond Pledge NDL guarantee). The hail size is left blank on the specimen hail-coverage forms GAF publishes (“hail impact up to ___ inches in diameter” on the two Diamond Pledge forms); the forms do not state a size (hail coverage form, enhanced wind and hail coverage form, hail resistance limited warranty form). Ask for the figure on the guarantee being offered. We did not read other makers' guarantee documents, so this is not a comparison between them.
What do Denver's sun and cold mean for a membrane?
More ultraviolet exposure than at sea level, and winter days that cross the freezing point. On ultraviolet, the EPA's UV Index method states: “UV intensity increases about 6% per kilometer elevation above sea level” ( EPA). The U.S. Geological Survey lists Denver's elevation at 5,130 to 5,470 feet (USGS), about 1.6 kilometers, so by the EPA's rule of thumb that is roughly a tenth more UV than at sea level before clouds and ozone are counted. That multiplication is ours.
On cold, the National Weather Service lists Denver's normal January high at 44°F or 45°F and its normal low at 18°F or 19°F (NWS Boulder): a normal January day starts well below freezing and ends above it.
Manufacturers describe their membranes as made for both. Johns Manville makes its TPO “using an ultraviolet-resistant thermoplastic polyolefin formulation” (Johns Manville, TPO) and its PVC from “an ultraviolet-resistant polyvinyl chloride” (Johns Manville, PVC); Elevate says its EPDM membranes “provide durable resistance to ultraviolet radiation, ozone, weathering and changing temperatures” (Elevate, EPDM). We did not find a standard or manufacturer document that puts a number on what Denver's altitude or its freeze-thaw cycling does to a membrane's life, so this page does not give one.
Which membrane is used where?
The manufacturers describe overlapping uses and a few leanings.
- TPO.Elevate: “TPO roofing is often chosen for its brightness, installation flexibility, and overall value” (Elevate, TPO). Carlisle describes its TPO as “designed for new roof construction and re-roofing applications.”
- PVC.Elevate, on its TPO page: “PVC roofing systems may be preferred for projects with more exposure to grease, chemicals, fire, puncture, or other harsh rooftop conditions.” Johns Manville says its PVC membranes offer “resistance to harsh chemicals and industrial pollutants” (Johns Manville, PVC). GAF's PVC data sheet lists “Increased protection against chemicals compared to TPO, EPDM, and asphaltic” and footnotes it: “GAF warranties and guarantees do not provide coverage against chemical exposure or exposure to grease, animal fats, and jet fuel” ( GAF PVC data sheet). Carlisle, for its part, claims for its TPO “chemical resistance to acids, bases and restaurant exhaust emissions” (Carlisle TPO data sheet), so ask each manufacturer about the specific exposure on your roof.
- EPDM.Elevate: EPDM “is well suited for a wide range of climates because the synthetic rubber membrane remains flexible for an extended period and performs across changing temperatures,” and its systems “can be adhered, mechanically attached, or ballasted” (Elevate, EPDM).
Elevate's own summary is the fair one: “The right membrane depends on the building, roof assembly, and project needs.”
Where do modified bitumen and built-up roofing fit?
They are the asphalt-based alternatives, built from more than one layer. For built-up roofing, Johns Manville describes a membrane “field-fabricated with layers of bitumen, alternating with plies of reinforcing felts,” and says that its “redundant layers give roofs exceptional resistance to water and weather” (Johns Manville, BUR). Elevate describes its built-up felts as “installed in multiple layers with a flood coat and aggregate” (Elevate, asphalt systems).
Modified bitumen is asphalt blended with a polymer and made into reinforced sheets. Elevate says its SBS membranes use “a synthetic rubber-based technology which yields exceptional flexibility, even in extremely low temperatures,” come “in smooth or granule surfaces,” and “can be installed with self-adhered technology, hot asphalt, cold adhesive, heat welding, or mechanically fastened” (Elevate, SBS). Both systems are covered by the same FM 4470 hail ratings as single-ply.
How is each membrane repaired?
With the same method that makes its seams, as far as the documents we read go. The TPO specification requires that the sheet be “capable of being heat welded, fused, or adhesively bonded to itself for making watertight field splices and repairs” (ASTM D6878). Weathering affects welding: Carlisle's TPO data sheet says membrane “that has been exposed to the weather must be prepared with Weathered Membrane Cleaner prior to hot-air welding” ( Carlisle TPO data sheet). For EPDM, Johns Manville's line includes flashings and cover strips with factory-applied pressure-sensitive tape (Johns Manville, EPDM).
We did not find a manufacturer document that compares how easily the three are repaired after years in service, so this page does not rank them. A repair on a roof under a manufacturer's warranty is governed by that warranty: ask who is allowed to make it and with what materials.
How long does each membrane last?
None of the three ASTM scopes gives a service life in years, and the manufacturer that answers the question directly says it depends on the project. Elevate on TPO: “The TPO roof lifespan depends on system design, membrane selection, installation quality, climate, rooftop conditions, and ongoing maintenance.” Elevate on EPDM: “Actual roof service life will vary by project.” Manufacturers also describe their track records, as when Versico says its EPDM “has over 60 years of proven performance”; that is a statement about a product's history, not a prediction for a roof.
What manufacturers do publish is warranty terms, and those are not the same thing. Elevate says eligible TPO assemblies “may qualify for Red Shield Limited Warranty coverage for up to 30 years,” and then: “Warranty term should not be treated as the same as expected roof service life.” For EPDM, Elevate says: “Qualifying 90-mil adhered RubberGard Platinum EPDM systems may be eligible for up to a 30-year limited warranty,” and Versico lists one of its EPDM membranes as eligible for “up to 20-year warranties.” Carlisle notes that its 80-mil TPO in special colors is “limited to warranties up to 20 years.” GAF's data sheets say its EverGuard TPO “Offers guarantees for eligible systems up to 20 years for 45 mil, 25 years for 60 mil, and 30 years for 80 mil” ( GAF TPO data sheet) and that for its EverGuard PVC “Guarantees are available up to 30 years for qualified systems” (GAF PVC data sheet), each with the footnote “Additional requirements apply”; its guarantee comparison page gives the maximum coverage period of the Diamond Pledge NDL Roof Guarantee as “Up to 35 Years (for qualifying systems)” (GAF guarantees page). These are examples for particular products, not a ranking of the membranes. The available term depends on membrane thickness, attachment method and the rest of the assembly, and each warranty has its own conditions. Read the warranty for the system you are being offered.
Maintenance is one of the factors Elevate names.
Questions to ask
- Which membrane, which thickness and which attachment method are you proposing, and why for this building?
- What is on or near this roof that the membrane has to tolerate: kitchen exhaust, chemicals, foot traffic, rooftop equipment?
- What FM 4470 hail rating does the whole assembly carry, and which cover board is under the membrane?
- Is my building 25,000 square feet or larger, and if so, how will this roof meet Denver's Green Buildings Ordinance?
- Is this a replacement or a recover, and does it trigger the energy code's insulation requirement?
- If the new roof is a cool roof and the old one was not, how is condensation being handled?
- What are the product's rated solar reflectance and thermal emittance, new and at three years?
- Which manufacturer warranty is offered, for how many years, what does it exclude, and what maintenance does it require?
- Who may repair the roof during the warranty, and how are repairs made on this membrane once it has weathered?
Which of these systems does Red Hawk Roofing install?
All of them. Our commercial roofing page lists the systems: TPO, EPDM, PVC, modified bitumen, built-up roofing and standing-seam metal. Red Hawk installs, repairs and maintains commercial roofs for property owners and managers in Denver and across Colorado's Front Range, and is a GAF Certified Commercial Contractor. GAF is quoted above from its own published documents, as the other manufacturers are.
Request a commercial roofing estimate, or call (720) 771-8921.
This guide is general information. Product data, ratings, warranty terms and city requirements change; the manufacturer's current documents, your insurer's requirements and the City and County of Denver's current rules are the authority, not this page.
Sources
Each source below was opened and read on November 22, 2026, unless its entry gives a later date. Laws, regulations, product instructions and warranty terms change; the linked document is the authority, not this page.
- ASTM International, D6878/D6878M-26: Standard Specification for Thermoplastic Polyolefin-Based Sheet RoofingThe published abstract and scope. The body of the standard is sold, not posted, and was not read.
- ASTM International, D4637/D4637M-15(2026): Standard Specification for EPDM Sheet Used in Single-Ply Roof MembraneThe published scope. The body of the standard was not read.
- ASTM International, D4434/D4434M-21: Standard Specification for Poly(Vinyl Chloride) Sheet RoofingThe published abstract and scope. The body of the standard was not read.
- Carlisle SynTec Systems, Sure-Weld TPO Reinforced Membrane Product Data SheetSheet dated January 28, 2026 (reprint code 600515): overview, features, precautions and the radiative properties table.
- Carlisle SynTec Systems, Sure-Flex PVC Membrane Product Data SheetSheet dated October 10, 2025: overview, installation, features and the radiative properties table.
- Carlisle SynTec Systems, FM's VSH Testing: Very Severe HailArticle on FM's hail classifications and the very severe hail region, as currently published.
- Elevate (Holcim), TPO Roofing SystemsProduct overview and the questions and answers on seams, PVC, reflectivity, lifespan and warranty.
- Elevate (Holcim), EPDM Roofing SystemsProduct overview and the questions and answers on seams, climate, lifespan and warranty.
- Elevate (Holcim), Asphalt Roofing SystemsOverview of built-up, SBS and APP modified bitumen systems.
- Elevate (Holcim), SBS Modified Bitumen Roofing SystemsProduct overview.
- GAF, EverGuard TPO 45, 60, 80 mil Data SheetRead November 27, 2026. Sheet COMEG876-PDF-0726: features, footnotes, the reflectivity table and the applicable standards.
- GAF, EverGuard PVC Data SheetRead November 27, 2026. Sheet COMEG992-PDF-1126: features, footnotes, the reflectivity table and the applicable standards.
- GAF, Commercial Roof Warranties and GuaranteesRead November 27, 2026. The comparison chart row for maximum coverage period.
- GAF, EverGuard Diamond Pledge NDL Roof GuaranteeRead November 27, 2026. Form COMTS700-1224: exclusions from coverage, item 2.
- GAF, EverGuard Diamond Pledge NDL Roof Guarantee: Hail CoverageRead November 27, 2026. Form COMTS728-1224: the hail coverage paragraph, where the hail diameter is a blank.
- GAF, EverGuard Diamond Pledge NDL Roof Guarantee: Enhanced Wind & Hail CoverageRead November 27, 2026. Form COMTS728E-1224: the hail coverage paragraph, where the hail diameter is a blank.
- GAF, EverGuard Hail Resistance Limited WarrantyRead November 27, 2026. Form dated 8/20: exclusions from coverage, item 3, where the hail diameter is a blank.
- Johns Manville, TPO Roofing SystemsProduct overview.
- Johns Manville, PVC Roofing SystemsProduct overview and membrane descriptions.
- Johns Manville, EPDM Roofing SystemsProduct overview and the membrane and accessory list, which includes white EPDM and tape-backed flashings.
- Johns Manville, BUR Roofing SystemsProduct overview.
- Sika, Sarnafil G 410-60 Product Data SheetVersion 06.01, November 2023: product description and characteristics.
- Sika, Sarnafil Hail PerformanceThe opening statement on very severe hail approvals.
- Versico Roofing Systems, VersiGard Black EPDM Non-Reinforced QA Membrane Technical Data BulletinBulletin VE-8501, dated July 10, 2025: overview, features and seam technology.
- Cool Roof Rating Council, What is a Cool Roof?The definitions of solar reflectance and thermal emittance and how the council rates products.
- U.S. Environmental Protection Agency, ENERGY STAR: Roof Products Specification Version 3.0The notice that the roof products specification was sunset on June 1, 2022.
- City and County of Denver, Energy Code for Existing Commercial Building ProjectsThe roof work questions and the Green Buildings Ordinance triggers, as currently published.
- City and County of Denver, Denver's Green Buildings OrdinanceWhich projects the ordinance applies to and which it does not.
- FM Approvals, Class Number 4470: Examination Standard for Single-Ply, Polymer-Modified Bitumen Sheet, Built-Up Roof and Liquid Applied Roof AssembliesEdition of April 2022: section 4.4, Hail Damage Resistance.
- Insurance Institute for Business & Home Safety, Commercial Roofs Best Practices GuideThe “Hail” section: FM 4470 and the recommended rating for low-slope roofs.
- U.S. Environmental Protection Agency, Calculating the UV IndexThe elevation adjustment in the UV Index calculation.
- U.S. Geological Survey, Elevations and Distances in the United StatesThe table of elevations of the 50 largest cities: Denver's high and low points.
- National Weather Service, Boulder office: Denver Daily Normals and Records, JanuaryNormal daily highs and lows, from 1991 to 2020 data.

